Superior NMC004-TD Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
8
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Electronic Appliance Checkout
To light the burner, turn ‘ON’ the optional
remote wall switch and turn the gas control
switch to the “ON” position. Ensure the ignitor
lights the pilot. The pilot flame should engulf
the flame rod as shown in
Figure 11
.
Figure 11
With proper care and maintenance, your ap-
pliance will provide many years of enjoy-
ment. If you should experience any problem,
first refer to the trouble shooting guide in this
manual. If problem persists, contact your
Lennox distributor.
With proper care and maintenance, your ap-
pliance will provide many years of enjoy-
ment. If you should experience any problem,
first refer to the trouble shooting guide in this
manual. If problem persists, contact your
Lennox distributor.
WIRING DIAGRAM
The wiring diagrams are provided here for
reference purposes only
(Figures 12, 13 and
14 on page 9)
. This information is also pro-
vided on schematics found on pullout lighting
instruction labels located within the control
compartment attached to the gas control valve.
CAUTION: LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING CON-
TROLS. WIRING ERRORS CAN CAUSE IM-
PROPER AND DANGEROUS APPLIANCE OP-
ERATION.
SIT and Honeywell Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
The top ³⁄₈" (10 mm) at the pilot generator
(thermopile) and the top ¹⁄₈" min (tip) of the quick
drop out thermocouple should be engulfed in the
pilot flame. The flame should project 1" (25 mm)
beyond the hood at all three ports (
Figure 9 - SIT,
Figure 10 - Honeywell
).
To light the burner, refer to the lighting in-
structions on
pages 12 and 13
for Honeywell
and SIT millivolt gas valves).
Figure 10
Figure 9
¹⁄₈" Min
(3 mm)
Thermocouple
Ignitor Rod
Hood
³⁄₈" Min
(9 mm)
Thermopile
MILLIVOLT HONEYWELL
Pilot
Nozzels
SIT MILLIVOLT
Thermocouple
Hood
Ignitor Rod
³⁄₈" Min
(9 mm)
Thermopile
Pilot
Nozzels
ELECTRONIC
Proper Flame
Adjustment
Pilot
Nozzle
3/8 To 1/2 Inch
(9 mm to 13 mm)
Ground
Electrode
Flame Rod
Hot Surface
Igniter
Vue de la page 7