3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 1
Millivolt Appliances -
To light millivolt appliances refer to the detailed
lighting instructions found in both English and
French on
pages 12 and 13
of these instruc-
tions respectively. Millivolt appliance lighting
instructions may also be found on the pull out
lighting instruction labels attached to the gas
control valve. Refer to
Figure 2
to locate the
appropriate location for the piezo ignitor used
with your appliance.
Millivolt appliances may be fitted with an op-
tional ON/OFF Rocker Switch for appliance ON/
OFF control. The optional ON/OFF Rocker switch
will be installed at either the right or the left side
of the Piezo Ignitor on the Piezo Bracket, just
beneath the valve. Once the pilot is lighted, the
ON/OFF rocker switch will control the appliance
ON/OFF operation. To operate: Toggle the
switch between its ON and OFF positions.
If your millivolt appliance is equipped with an
optional remote wall switch or remote control
kit and the pilot is lit, the appliance main burner
may be turned on and off with the wall switch or
remote control.
Electronic Appliances -
To light electronic appliances refer to the de-
tailed lighting instructions found in both En-
glish and French on
pages 14 and 15
of these
instructions respectively. Electronic appliance
lighting instructions may also be found on
the pull out lighting instruction labels at-
tached to the gas control valve. If your elec-
tronic appliance is equipped with an optional
remote wall switch or remote control kit the
appliance main burner may be turned on and
off with the wall switch or remote control.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled through
a remotely located optional wall switch. Sepa-
rate switches may provide independent con-
trol for the remote controlled fireplace opera-
tion (optional equipment). In lieu of remote or
remote wall switch operation, the appliance
must be operated directly through the controls
located on the front of the valve located within
the control compartment located behind the
hinged drop down panel below the appliance
front glass enclosure panel,
Figure 1
.
Gas Controls/Control Compartment Access
The gas controls can be found within the con-
trol compartment behind the hinged drop-down
control compartment access panel comprising
the lower front face of the appliance below the
front glass enclosure panel.
To open the control compartment access panel,
actuate the spring loaded magnetic catches se-
curing the door by gently depressing the outer
top corners of the door until the catches "pop" the
door free, allowing it to swing out and down to
open. Once the control compartment door is
opened, complete access to the gas control
valve and its related controls is attainable.
To ease door closure, depress the catches to
place them in their retracted position until they
stay there, then close the door.
Operation of millivolt and electronic gas control
systems are different. Before lighting and op-
erating your appliance determine if you have a
millivolt or electronic appliance.
Refer to Fig-
ure 1
to access the control compartment. Mil-
livolt appliances will be fitted with the gas
control valve shown in
Figure 2
.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURES. USE
CAUTION AROUND THE APPLIANCE TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE IN
THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING
OR OTHER FLAMMABLE MATERIALS
ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES
ENFANTS. GARDER LES VÊTEMENTS,
LES MEUBLES, L'ESSENCE OU AUTRES
LIQUIDES À VAPEUR INFLAMMABLES
LOIN DE L'APPAREIL.
WARNING: FAILURE TO COMPLY WITH
THE INSTALLATION AND OPERATING IN-
STRUCTIONS PROVIDED IN THIS DOCU-
MENT WILL RESULT IN AN IMPROP-
ERLY INSTALLED AND OPERATING AP-
PLIANCE, VOIDING ITS WARRANTY. ANY
CHANGE TO THIS APPLIANCE AND/OR
ITS OPERATING CONTROLS IS DANGER-
OUS. IMPROPER INSTALLATION OR USE
OF THIS APPLIANCE CAN CAUSE SERI-
OUS INJURY OR DEATH FROM FIRE,
BURNS, EXPLOSION OR CARBON MON-
OXIDE POISONING.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning are similar to the
flu with headaches, dizziness and/or nausea. If
you have these signs, obtain fresh air immedi-
ately. Turn off the gas supply to the appliance
and have it serviced by a qualified profes-
sional, as it may not be operating correctly.
Appliances with electronic systems will be fit-
ted with the electronic valve shown in
Figure 3
.
Familiarize yourself with the differing controls
for the valve your appliance uses.
Ne pas se servir de cet appareil s'il a été plongé
dans l'eau, complètement ou en partie. Appeler
un technicien qualifié pour inspecter l'appareil et
remplacer toute partie du système de contrôle et
toute commande qui ont été plongés dans l'leau.
Test gage connections are provided on the
front of the millivolt gas control valve (identi-
fied OUT for the manifold side and IN for inlet
pressure. A ¹⁄₈" NPT test gage connection is
provided on the electronic gas control valve
adjacent to the outlet to the main burner.
Minimum inlet gas pressure to these appliances
is 5.0 inches water column (1.24 kPa) for natural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to these
appliances is 10.5 inches water column (2.61
kPa) for natural gas and 13.0 inches water
column (3.23 kPa) for propane.
The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure test-
ing of the gas supply piping system at test
pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply piping
system during any pressure testing of that system
at pressures in excess of ¹⁄₂ psig (3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
Any safety guard or screen removed for servic-
ing the appliance must be replaced prior to
operating the appliance.
Piezo Ignitor
Drop Down
Control
Compartment
Access Panel
SIT Gas Valve
Honeywell
Gas Valve
Sit and Honeywell Millivolt Gas Valve Showing
Piezo Ignitor Location (Each Unit is Equipped with
Only One of these Gas Valves)